ARDD
controller

Control the energy
of every phase.

Precise power cutoff, active energy recovery and coordinated operation with the OW-RFMMC motor and RBT battery.

RAKTON DRIVE controller: boards, power stage and connections beneath a transparent enclosure

Less heat.
More useful power.

ARDD — Active Reverse Diagonal Discharge. Phase energy returns through the open channels of the power bridge’s opposite diagonal.

Diode return path

Current flows through body diodes D3 and D2.

Q1D1Q2D2Q3D3Q4D4i > 0ABMotor phase+−DCEnergy returned to the DC link

ARDD

Current flows through the open channels of Q3 and Q2.

Q1D1Q2D2Q3D3Q4D4i > 0ABMotor phase+−DCEnergy returned to the DC link

A longer useful POWER window

Cutoff strategies compared · window lengths not to scale
Cutoff with a margin ARDD · T_demag Margin Transition Longer POWER window Up to the half-cycle boundary Zero current is checked separately

Cutoff with a margin

ARDD · cutoff based on T_demag

Additional POWER window. Full current decay is checked separately.

Heat generation in the active pair

Identical initial conditions · calculation example

Conduction losses in two devices: D2 + D3 or the open channels of Q2 + Q3.

0200400020406080100120WTime after cutoff, µsDiodes · 432 WARDD · 205.6 W
020040004080120WAfter cutoff, µsDiodes · 432 WARDD · 205.6 W

Energy converted to heat during one recovery episode

Diodes20.99 mJ
ARDD7.06 mJ

2.97× lower loss energy in this calculation

Comparison conditions

300 V · initial current 60 A · 1000 rpm · Tj = 150 °C. Includes conduction losses in two devices; switching and initial dead time are excluded.

The curves use the supplied calculation example and compare losses in the energy-return path. The separate POWER strip illustrates T_demag-based cutoff; its lengths do not specify a numerical increase in output power.

Part of the platform.
Built around your requirements.

The controller, motor and battery form a coordinated system. Start with the controller or discuss the complete platform.

Development and manufacturing to customer requirements, technology licensing and integration support.

OW-RFMMC

Energy control for individual motor phases.

ARDD

T_demag-based cutoff and active energy recovery.

RBT

Coordinated power supply and energy exchange across the platform.

Let’s discuss your project.

Describe the application, supply voltage, currents and control requirements. You can also start with a question.

RaktonDrive@gmail.com

Your email app will open. You confirm sending.